ECS parts

Flow limiters

Flow limters
 

Flow limiter limits the quantity of air by throttling depending on the difference of air pressures at the front of and beyond the limiter.

LUN 5683.5-8,   LUN 5684.5-8

Water separator

Water separator
 

Water separator entraps a part of condensed water vapors in the cockpit air. It is installed in the cold section of the air-conditioning system after turbo-cooler.

LUN 5682.5-8
 

Air shower valve

Air shower valve
 

The air shower valve is designed for blowing over the pilot's face with cold or warm air. The blowing intensity is controlled by turning collar, which through the fork revolves a cone, which in turn is slid in or out, changing the cross sectional area of throughflow of the valve. The outlet part of the valve can be revolved in the valve joint to change the direction of blown air.

LUN 5675.52-8

Pressure control valve

Pressure control valve
 

The pressure control valve is a device which maintains a constant outlet pressure of air.

Pressure control valve is a pneumatic regulation device, which final control element allows warm air to floe into the cockpite air piping and maintains controlled air temperature in the piping.

LUN 5666-8,   LUN 5687.5-8
 
LUN 5669-8,   LUN 5688.5-8
 
LUN 5693-8,   LUN 5699-8
 

Turbocooler

Turbocooler
 

The turbocooler is a device designed for cooling the air supplied into the aircraft cockpit from the jet engine compressor via the air/air heat exchanger. Besides cooling of the aircraft cockpit, the expansion turbine of the turbocooler drives the turboblower, which suctions the atmospheric air through the heat exchanger.

LUN 5680.5-8

Precoolers

Precoolers
 

The precooler is designed for cooling the air flowing from the jet engine compressor in two separate compar

tments. LUN 5664-8,   LUN 5681.5-8
 

Geared motor

Geared motor
 

The geared motor is designed for driving the closing valve LUN 5663-8 and other equipment of aircraft systems, for which is torque and robustness are applicable.

LUN 5668-8

Closing valve

Closing valve
 

The closing valve closes the air supply from the compressor motor into the air-conditioning or defrosting circuit.

LUN 5663-8
 

Excess pressure regulator

Excess pressure regulator
 

Excess pressure regulator is designed for priority air supply into the special equipment branch.

LUN 5660-8

Thermostats

Thermostats
 

The thermostat with filter works as a temperature sensor on bi-metal principle, this property is used for regulation of air pressure control.

LUN 5689.5-8,   LUN 5690-8
 
LUN 5691.5-8,   LUN 5692-8
 

Inlet filter

Inlet filter
 

Inlet filter is a front device of the control branch of pneumatic control of the air-conditioning system. It supplies clean air for correct function of the pneumatic control equipment.

LUN 5685.5-8

Temperature selector

Temperature selector
 

Temperature selector is designed for fine regulation of pressure of control air supplied to the control valve nozzle.

LUN 5686.5-8